4.2.14 LIMIT Menu
The Limit menu displays the maximum available value for voltage, frequency and current range
of the power supply. This screen is used for information only and contains no user changeable
fields. The limit values shown cannot be changed.
ENTRY
DESCRIPTION
LIM VOLT
LOW
Low Voltage
Range
Displays maximum available output voltage in
the low voltage range.
LIM VOLT
HIGH
High Voltage
Range
Displays maximum available output voltage in
the high voltage range.
LIM VOLT
Xform
Extra Voltage
Range
Displays maximum available output voltage in
the extra voltage range. (HV or EV option)
LIM FREQ
LOW
Low Frequency
Limit
Displays minimum available output frequency.
LIM FREQ
HIGH
High Frequency
Limit
Displays maximum available output frequency
LIM CURR
C range
Displays maximum available current in low
voltage range at full power.
PHASE (C)
Phase Setting
Displays phase angle for phase C. Valid values
are 120 for three-phase or mode configuration,
0 for single-phase only configuration. Any other
value indicates split (2) phase configuration.
The MX15 is single phase only, so this will
always show a value of 0.