beautypg.com

Specifications, Electrical, 2 specifications – AMETEK MX15 Series User Manual

Page 11: 1 electrical

background image

User Manual

– Rev M

California Instruments

MX15

11

2 Specifications

Specifications shown are valid over an ambient temperature range of 25

5

C and apply after a

30 minute warm-up time. Unless otherwise noted, all specifications are for sine wave output into
a resistive load.

2.1 Electrical

2.1.1

Input

Parameter

MX15

MX30/2

MX45/3

Line Voltage:
(3 phase, 3
wire + ground
(PE))

208 V

LL

10%

230 V

LL

10%

400 V

LL

10%

480 V

LL

10%

Line VA:

18 KVA

35 KVA

53 KVA

Line Current:

58 A

RMS

@ 187 V

LL

52 A

RMS

@ 207 V

LL

30 A

RMS

@ 360 V

LL

25 A

RMS

@ 432 V

LL

Each MX15 chassis

requires its own AC

service.

Total Line currents are

2 x MX15

Each MX15 chassis

requires its own AC

service.

Total Line currents are

3 x MX15

Line
Frequency:

47-63 Hz

Efficiency:

85 % (typical) depending on line and load

Power Factor:

0.95 (typical) / 0.99 at full power.

Inrush Current:

77A

pk

@ 208 V

LL

73A

pk

@ 230

V

LL

44A

pk

@ 400

V

LL

37A

pk

@ 480

V

LL

Each MX15 chassis

requires its own AC

service.

Total Peak currents are

2 x MX15

Each MX15 chassis

requires its own AC

service.

Total Peak currents are

3 x MX15

Hold-Up Time:

> 10 ms

Isolation
Voltage:

2200 VAC input to output

1350 VAC input to chassis