beautypg.com

AMETEK MX15 Series User Manual

Page 157

background image

User Manual - Rev M

California Instruments

MX15

157

9.4.3

Test Revision

The MIL-STD 704 option is capable of performing all sub-sections of MIL-STD 704 revision D, E
or F. A selection is made available to specify the revision of standard to be applied to the EUT.
The MIL704 option defaults to Revision E.

9.4.4

Tests Performed

9.4.4.1

STEADY STATE

AC Mode:

1. Steady State Voltage and Frequency test

2. Waveform Distortion test

3. Voltage Modulation test

4. Voltage Unbalance test

5. Phase Unbalance test

6. Frequency Modulation test

7. Voltage Modulation test

8. Transient Voltage low and high test

9. Transient Frequency low and high test

DC Mode:

1. Steady State Voltage test

2. Ripple test

9.4.4.2

EMERGENCY STATE

AC Mode:

1. Emergency Voltage minimum and maximum test

2. Emergency Frequency minimum and maximum test

DC Mode:

1. Emergency Voltage minimum and maximum test

9.4.4.3

ABNORMAL STATE

AC Mode:

1. Abnormal Voltage under

2. Abnormal Voltage over

3. Abnormal Frequency under

4. Abnormal Frequency under

DC Mode:

1. Abnormal Voltage under

2. Abnormal Voltage over