Unpacking and installation, Unpacking, Power requirements – AMETEK MX15 Series User Manual
Page 34: 3 unpacking and installation, 1 unpacking, 2 power requirements
User Manual
– Rev M
California Instruments
MX15
34
3 Unpacking and Installation
3.1 Unpacking
Inspect the unit for any possible shipping damage immediately upon receipt. If damage is
evident, notify the carrier. DO NOT return an instrument to the factory without prior approval. Do
not destroy the packing container until the unit has been inspected for damage in shipment. If
possible, retain the container (wooden crate) in the event the system ever has to be returned to
the factory for either repair or upgrades
WARNING: This power source weighs approximately 600 lbs / 272
. Obtain
adequate help when moving the unit. Make sure the location (floor) in which the MX
Series unit(s) will be installed can support the weight of the unit(s).
3.2 Power Requirements
The MX Series power Source has been designed to operate from a three-phase, three wire (Wye
or Delta) AC input line. A protective earth connection is required as well. (PE).
Available three-phase input settings are 208 V
LL
(option -208), 230 V
LL
(option -230), 400 V
LL
(option -400), 440 V
LL
(option -440), or 480 V
LL
(option -480).
Figure 3-1: The MX15 Power Source
CAUTION: Do not connect 400, 440, or 480V into a unit set for 208 or 230V unit, the
result could be a severely damaged unit. Always check the input rating on the model
number tag before connecting AC input power. Consult factory if input settings have
to be changed.