beautypg.com

AMETEK MX15 Series User Manual

Page 13

background image

User Manual

– Rev M

California Instruments

MX15

13

Output Parameter

MX15

MX30/2

MX45/3

Constant Power Mode:

Operation at higher currents but constant power is possible from 80% of Voltage range
(125% of max. current) declining to 100% of maximum current at 100 % of voltage range
for short periods of time or at reduced ambient temperatures. (< 15 mins @ 30° C). See
Figure 2-2 and Figure 2-4.

AC Mode

MX15-1
V Lo: 100 A
V Hi: 50 A

MX30/2-1
V Lo: 200 A
V Hi: 100 A

MX45/3-1
V Lo: 300 A
V Hi: 150 A

DC Mode

AC+DC Mode

MX15-1
V Lo: 50 A
V Hi: 25 A

MX30/2-1
V Lo: 100 A
V Hi: 50 A

MX45/3-1
V Lo: 150 A
V Hi: 75 A

Note:

Current derates linearly from 50% of voltage range to 20% of specified current at 5% of
voltage range

Current Limit mode

Programmable, CC or CV mode

Repetitive Peak Current

AC Mode

MX15-1

V Lo: 300 A
V Hi: 150 A

MX30/2-1

V Lo: 600 A
V Hi: 300 A

MX45/3-1

V Lo: 900 A
V Hi: 450 A

Frequency

Range:

Standard:

16 Hz - 819.0 Hz

-LF option:

16 Hz - 500.0 Hz

-HF option:

16 Hz

– 900 Hz

Resolution:

0.01 Hz

from 16.00 to 81.91 Hz

0.1 Hz

from 82.0 to 819.0 Hz

1 Hz

from 819 to 900 Hz

Accuracy:

± 0.01 %

Ext. Sync Mode

Input:

Isolated TTL input for external frequency control. Requires 5V at 5 mA for
logic high.

Accuracy:

Ext. Sync to phase A with fixed Ext. Sync Frequency input:
16 Hz - 100 Hz: < 2°
100 Hz - 500 Hz: < 3°
> 500 Hz:

< 4°

Programmable Output Impedance

Range:

R: 1

– 200 mOhm

L: 15

– 200 uH

N/A

N/A

Resolution:

R: 1 mOhm

L: 1 uH

N/A

N/A

Accuracy:

10 % FS

N/A

N/A

Note: Output specifications apply below the Current / Voltage rating lines shown in the