AMETEK MX15 Series User Manual
Page 13
User Manual
– Rev M
California Instruments
MX15
13
Output Parameter
MX15
MX30/2
MX45/3
Constant Power Mode:
Operation at higher currents but constant power is possible from 80% of Voltage range
(125% of max. current) declining to 100% of maximum current at 100 % of voltage range
for short periods of time or at reduced ambient temperatures. (< 15 mins @ 30° C). See
Figure 2-2 and Figure 2-4.
AC Mode
MX15-1
V Lo: 100 A
V Hi: 50 A
MX30/2-1
V Lo: 200 A
V Hi: 100 A
MX45/3-1
V Lo: 300 A
V Hi: 150 A
DC Mode
AC+DC Mode
MX15-1
V Lo: 50 A
V Hi: 25 A
MX30/2-1
V Lo: 100 A
V Hi: 50 A
MX45/3-1
V Lo: 150 A
V Hi: 75 A
Note:
Current derates linearly from 50% of voltage range to 20% of specified current at 5% of
voltage range
Current Limit mode
Programmable, CC or CV mode
Repetitive Peak Current
AC Mode
MX15-1
V Lo: 300 A
V Hi: 150 A
MX30/2-1
V Lo: 600 A
V Hi: 300 A
MX45/3-1
V Lo: 900 A
V Hi: 450 A
Frequency
Range:
Standard:
16 Hz - 819.0 Hz
-LF option:
16 Hz - 500.0 Hz
-HF option:
16 Hz
– 900 Hz
Resolution:
0.01 Hz
from 16.00 to 81.91 Hz
0.1 Hz
from 82.0 to 819.0 Hz
1 Hz
from 819 to 900 Hz
Accuracy:
± 0.01 %
Ext. Sync Mode
Input:
Isolated TTL input for external frequency control. Requires 5V at 5 mA for
logic high.
Accuracy:
Ext. Sync to phase A with fixed Ext. Sync Frequency input:
16 Hz - 100 Hz: < 2°
100 Hz - 500 Hz: < 3°
> 500 Hz:
< 4°
Programmable Output Impedance
Range:
R: 1
– 200 mOhm
L: 15
– 200 uH
N/A
N/A
Resolution:
R: 1 mOhm
L: 1 uH
N/A
N/A
Accuracy:
10 % FS
N/A
N/A
Note: Output specifications apply below the Current / Voltage rating lines shown in the
V/I rating chart below.