9.4.6
Steady State AC Tests
Scroll to the NORMAL ST MENU entry using the up and down cursor keys. Press the ENTER
key to select the STEADY STATE screens. The screen will appear as shown in Figure 9-12
Figure 9-12: Steady State Menu
The MIL704 Steady state screens have the following tests:
1. VOLTAGE
2. FREQUENCY
3. VOLT UNBALANCE
4. PHASE DIFFERENCE
5. VOLT MODULATION
6. FREQ MODULATION
7. VOLT TRANSIENT
8. FREQ TRANSIENT
9. DISTORTION
The above tests can be selected by scrolling to the highlighted selection using the up and down
cursor keys and the ENTER key to start the selected test.
VOLTAGE
This test will change the output voltage in the sequence shown in Table 9-12.
SEQUENCE
VOLTAGE
TIME
400Hz/VFREQ
60Hz only
1
108
110
1 minute
2
118
125
1 minute
3
115
115
1 minute
Table 9-12: Steady state voltage
The
key (backspace) will terminate the test at any time.
FREQUENCY
This test will change the output frequency in the sequence shown in Table 9-13.
SEQUENCE
FREQUENCY
TIME