beautypg.com

AMETEK MX15 Series User Manual

Page 16

background image

User Manual

– Rev M

California Instruments

MX15

16


2.1.3

AC Measurements

Measurement specifications apply to MX15-1 / MX15-1Pi. See notes for other models and
configurations.

Parameter

Range

Accuracy (

)

Resolution

Frequency

16.00 - 820.0 Hz

0.01% + 0.01 Hz

0.01 to 81.91 Hz
0.1 to 500 Hz

RMS Voltage

0 - 400 Volts

0.05V + 0.02%, <100 Hz

0. 1V + 0.02%, 100-820 Hz

0.01 Volt

RMS Current

0 - 150 Amps

0.15A + 0.02%, <100 Hz

0. 3A + 0.02%, 100-820 Hz

0.01 Amp

Peak Current

0 - 400 Amps

0.15A + 0.02%, <100 Hz

0. 3A + 0.02%, 100-820 Hz

0.01 Amp

VA Power

0 - 15 KVA

30 VA + 0.1%, <100 Hz

60 VA + 0.1%, 100-820 Hz

10 VA

Real Power

0 - 15 KW

30 W + 0.1%, <100 Hz
60 W + 0.1%, 100-820 Hz

10 W

Power Factor
(>0.2kVA)

0.00 - 1.00

0.01, <100 Hz
0.02, 100-820 Hz

0.01

Note: Accuracy specifications are valid above 100 counts. For current and power measurements,
specifications apply from 2% to 100% of measurement range.

Note: Power factor accuracy applies for PF > 0.5 and VA > 50 % of max.

Current

(DC)

Voltage (DC)

60

50

40

30

20

10

0

20 40 100 150 200 300 400

62.5 A

31 A

25 A

Full
Pow er

Full
Pow er

Figure 2-4: Voltage / Current Rating Chart for 200/400 V DC Ranges

– Derated