beautypg.com

AMETEK MX15 Series User Manual

Page 48

background image

User Manual

– Rev M

California Instruments

MX15

48

3.6.4

Multi-Chassis Output Connections

If two or more MX15 chassis are used to form a single power system, the outputs of all chassis
need to be combined (paralleled). This can be done directly at the EUT if convenient or using
the provided heavy-duty terminal block. One 2-position block is provided. This block allows up to
four wires to be combined into one larger wire gauge size wire. The outputs of the 2 or 3 MX15
chassis are connected on one side of these blocks. The EUT can be connected to the other side.
Note that the wire size to the EUT should be sized up to accommodate the double or triple
currents per phase.

The dimensions of the supplied terminal block are shown in Figure 3-11.

Figure 3-11: Ship kit Terminal Block dimensions