2.1.4

DC Measurements

Parameter

Range

Accuracy (

)

Resolution

Voltage

0 - 400 Volts

0.5 Volts

0.1 Volt

Current

0 - 400 Amps

0.5 Amps

0.01 Amp

Power

0 - 10 kW

30 W

10 W

Note: Accuracy specifications are valid above 100 counts. For current and power measurements,
specifications apply from 2% to 100% of measurement range.

2.1.5

Harmonic Measurements (Pi controller)

Parameter

Range

Accuracy (

)

Resolution

Frequency fundamental

16.00 - 820 Hz

0.03% + 0.03 Hz

0.01 Hz

Frequency harmonics 32.00 Hz

– 16 KHz

0.03% + 0.03 Hz

0.01 Hz

Phase

0.0 - 360.0°

2° typ.

0.5°

Voltage

Fundamental

0.75V

0.01V

Harmonic 2 - 50

0.75V + 0.3% + 0.3%/kHz

0.01V

Current

Fundamental

0.5A

0.1A

Harmonic 2 - 50

0.15A + 0.3% + 0.3%/kHz

0.1A

Note: Accuracy specifications are valid above 100 counts. For current and power measurements,
specifications apply from 2% to 100% of measurement range.

2.1.6

System Specification

Parameter

Specification

External Modulation:

0 to 10%

Synchronization
Input:

Isolated TTL input for external frequency control. Requires 5V at 5 mA for
logic high.

Trigger Input:

External trigger source input. Requires TTL level input signal. Triggers on
negative edge. Response time 80 - 100

s.

Trigger Output:

Programmable through transient list system. 400

s pulse for voltage or

frequency change. Isolated TTL output. Output reverts to Function strobe
when not used as Trig Out. This function is mutually exclusive with the
Function Strobe output.

Function Strobe:

Active for any voltage or frequency program change. 400

s pulse for voltage

or frequency change. Isolated TTL output. This function is mutually exclusive
with the Trigger Output. Same output is used for Trigger Output if Trigger
Output is programmed as part of list system.

Output Status:

Monitors status of output relay. Isolated TTL output. High if output relay is
closed, low if output relay is open.

Non volatile memory
storage:

16 complete instrument setups and transient lists, 100 events per list.

Waveforms

Sine (Models with Standard controller)

Sine, square, clipped, user defined (Models with Pi controller)

Transients

Voltage: drop, step, sag, surge, sweep