beautypg.com

AMETEK MX15 Series User Manual

Page 54

background image

User Manual

– Rev M

California Instruments

MX15

54

3.7.6

USB Interface

A standard USB Series B device connector is located on the rear panel for remote control. A
standard USB cable between the AC Source and a PC or USB Hub may be used.

Note: Use of the USB port to control more than one power source from a single PC is

not recommended, as communication may not be reliable. Use GPIB interface for
multiple power source control.

Figure 3-13: USB Connector pin orientation.

Pin

Name

Description

1

VBUS

+5 VDC

2

D-

Data -

3

D+

Data +

4

GND

Ground

Table 3-9: USB Connector pin out.