Supplemental specifications, 7 supplemental specifications – AMETEK MX15 Series User Manual
Page 29
![background image](https://www.manualsdir.com/files/771676/content/doc029.png)
User Manual
– Rev M
California Instruments
MX15
29
2.7 Supplemental Specifications
Supplemental specifications are not warranted and generally reflect typical performance
characteristics. These characteristics are have been checked on a type test basis only and are
not verified on each unit shipped. They are provided for reference only.
2.7.1
Output
Output Parameter
MX15
MX30/2
MX45/3
Voltage:
Slew rate:
> 0.5 V/micro sec
Stability:
0.25 % over 24 hour period at constant line, load and temperature.
Settling time:
< 0.5 msec
Frequency:
Temperature
coefficient:
5ppm per degree C
Stability:
15 ppm per year
Current:
Constant Power
Mode:
Operation at higher currents but constant power is possible from 80% of
Voltage range (125% of max. current) declining to 100% of maximum current
at 100 % of voltage range for short periods of time or at reduced ambient
temperatures. (< 15 mins @ 30° C). See Figure 2-2 and Figure 2-4.
2.7.2
Acoustic Noise Levels
Acoustic Noise:
Measured at a distance of one meter. (3 ft.)
Front
53 dBA at no load to 65 dBA at full load.
Back
55 dBA at no load to 67 dBA at full load