2.7 Supplemental Specifications

Supplemental specifications are not warranted and generally reflect typical performance
characteristics. These characteristics are have been checked on a type test basis only and are
not verified on each unit shipped. They are provided for reference only.

2.7.1

Output

Output Parameter

MX15

MX30/2

MX45/3

Voltage:

Slew rate:

> 0.5 V/micro sec

Stability:

0.25 % over 24 hour period at constant line, load and temperature.

Settling time:

< 0.5 msec

Frequency:

Temperature
coefficient:

5ppm per degree C

Stability:

15 ppm per year

Current:

Constant Power
Mode:

Operation at higher currents but constant power is possible from 80% of
Voltage range (125% of max. current) declining to 100% of maximum current
at 100 % of voltage range for short periods of time or at reduced ambient
temperatures. (< 15 mins @ 30° C). See Figure 2-2 and Figure 2-4.

2.7.2

Acoustic Noise Levels

Acoustic Noise:

Measured at a distance of one meter. (3 ft.)

Front

53 dBA at no load to 65 dBA at full load.

Back

55 dBA at no load to 67 dBA at full load