beautypg.com

Halt halt – Zilog Z80380 User Manual

Page 96

background image

5-62

Z380

U

SER

'

S

M

ANUAL

DC-8297-03

Z

ILOG

HALT
HALT

HALT

Operation:

CPU Halts

The CPU operation is suspended until either an interrupt request or reset request is
received. This instruction is used to synchronize the CPU with external events, preserving
its state until an interrupt or reset request is accepted. After an interrupt is serviced, the
instruction following HALT is executed. While the CPU is halted, memory refresh cycles still
occur, and bus requests are honored. When this instruction is executed the signal /HALT
is asserted and remains asserted until an interrupt or reset request is accepted.

Flags:

S:

Unaffected

Z:

Unaffected

H:

Unaffected

V:

Unaffected

N:

Unaffected

C:

Unaffected

Addressing

Execute

Mode

Syntax

Instruction Format

Time

Note

HALT

01110110

2