beautypg.com

Out output (byte) – Zilog Z80380 User Manual

Page 155

background image

5-121

Z380

U

SER

'

S

M

ANUAL

Z

ILOG

DC-8297-03

OUT

OUTPUT (BYTE)

OUT (C),src

src = R, IM

Operation:

(C)

src

The byte of data from the source is loaded into the selected peripheral. During the I/O
transaction, the contents of the 32-bit BC register are placed on the address bus.

Flags:

S:

Unaffected

Z:

Unaffected

H:

Unaffected

V:

Unaffected

N:

Unaffected

C:

Unaffected

Addressing

Execute

Mode

Syntax

Instruction Format

Time

Note

R:

OUT (C),R

11101101 01 -r- 001

3+o

IM:

OUT (C),n

11101101 01110001 —n—

3+o

Field Encodings:

r: per convention