Mlt multiply unsigned (byte) – Zilog Z80380 User Manual
Page 138
5-104
Z380
™
U
SER
'
S
M
ANUAL
DC-8297-03
Z
ILOG
MLT
MULTIPLY UNSIGNED (BYTE)
MLT R
src = R
Operation:
R(15-0)
←
R(7-0) x R(15-8)
The contents of the upper byte of the source register are multiplied by the contents of the
lower byte of the source register and the product is stored in the source register. Both
operands. Both operands are treated as unsigned, binary integers.
Flags:
S:
Unaffected
Z:
Unaffected
H:
Unaffected
V:
Unaffected
N:
Unaffected
C:
Unaffected
Addressing
Execute
Mode
Syntax
Instruction Format
Time
Note
R:
MLT R
11101101 01rr1100
7
Field Encodings:
rr: 00 for BC, 01 for DE, 10 for HL, 11 for SP
See also other documents in the category Zilog Sensors:
- S3F94C8 (11 pages)
- S3F80QB (29 pages)
- S3F8S19 (38 pages)
- Z51F6412 (54 pages)
- Z51F6412 (55 pages)
- Z51F6412 (96 pages)
- EZ80F93 (11 pages)
- Z16F6411 (20 pages)
- Z16F6411 (216 pages)
- EZ80F93 (13 pages)
- ZMOT0BSB (314 pages)
- ZMOT0BSB (582 pages)
- Z8F083A (14 pages)
- Z8F2480 (17 pages)
- Z8F082A (18 pages)
- Z8F082A (15 pages)
- Z8F0822 (17 pages)
- Z8F6423 (83 pages)
- Z8F2480 (18 pages)
- Z8F2480 (19 pages)
- Z8F6423 (18 pages)
- Z8F6423 (27 pages)
- Z8F6482 (50 pages)
- EZ80L92 (26 pages)
- EZ80L92 (79 pages)
- EZ80F91GA (469 pages)
- EZ80F915 (411 pages)
- EZ80F91NAA (34 pages)
- EZ80F91 (41 pages)
- EZ80L92 (40 pages)
- EZ80L92 (10 pages)
- eZ80F92 (87 pages)
- Z16FMC6 (41 pages)
- ZUSBOPTS (38 pages)
- ZUSBOPTS (59 pages)
- Z16FMC6 (520 pages)
- Z8FMC16 (26 pages)
- Z16FMC6 (8 pages)
- Z16FMC6 (26 pages)
- ZMOT1AHH (25 pages)
- ZMOT0BSB (34 pages)
- EZ80F915 (78 pages)
- EZ80190 (87 pages)
- EZ80L92 (86 pages)
- EZ80F91GA (127 pages)