Altera High-Speed Development Kit, Stratix GX Edition User Manual
Page 65

Altera Corporation
Quartus II Version 3.0
5–21
Perform the Production Diagnostic Tests
Perform the Standard Tests
5.
Press reset (GX_CLR).
6.
Press start (Stratix_GX_PB_0).
7.
Inject an error by pressing Stratix_GX_PB_2 (S4) once. The number
01 displays on the Stratix GX 7-segment display (D9) and Stratix GX
LED5 illuminates.
8.
Inject two more errors by pressing Stratix_GX_PB_2 (S4) twice. 03
displays on the Stratix GX 7-segment display (D9).
9.
Press start and then reset three times to insure that the test is
working.
10. If all of these tests pass, write the word “PASS” in the column under
Stratix GX in the row Stratix GX XPAK XCVR in the worksheet.
Gigabit Transceivers with HSSDC2 Interface (Stratix GX HSSDC2
XCVR) (GX40 Device Only)
For this test, perform the following steps.
1.
Change the XCVR setting to HSSDC2 by setting the Stratix GX user
dipswitch 6 to the down position, dipswitch 5 to the down position,
and dipswitch 4 to the up position.
2.
Press reset (GX_DEV CLR). This will initialize the design. The
GX_DEV_CLR LED should light up.
3.
Press start (GX PB0). Several LEDs illuminate. LED0, LED1, LED2,
and LED3 are the match lights on a per channel basis.
4.
Press reset. LED4 illuminates, indicating that the test is running.
LED5 is the error signal.
5.
Press stop (GX PB1) to stop the device from transmitting.
6.
Press reset (GX_CLR).
7.
Press start (Stratix_GX_PB_0).
8.
Inject an error by pressing Stratix_GX_PB_2 (S4) once. The number
01 displays on the Stratix GX 7-segment display (D9) and Stratix GX
LED5 illuminates.
9.
Inject two more errors by pressing Stratix_GX_PB_2 (S4) twice. 03
displays on the Stratix GX 7-segment display (D9).