Stratix gx-to-stratix bridge – Altera High-Speed Development Kit, Stratix GX Edition User Manual
Page 56

5–12
Quartus II Version 3.0
Altera Corporation
Perform the Standard Tests
High-Speed Development Kit, Stratix GX Edition User Guide
9.
If all of the tests pass, write “PASS” in the column under Stratix GX
in the User I/O row in Table 5–1 on page 5–36.
10. Test the user I/O for the Stratix device by performing steps 13
through 24 in “Run the User I/O Test” on page 4–3.
11. If all of the tests pass, write “PASS” in the column under Stratix in
the User I/O row in the worksheet (Table 5–1 on page 5–36).
Stratix GX-to-Stratix Bridge
For this test, perform the following steps in the Programmer.
1.
Change the programming file for the Stratix GX device to
GX40_Bridge.sof
.
2.
Change the programming file for the Stratix device to
STX40_Bridge.sof
. Wait until the checksum field is updated.
3.
Turn on the Program/Configure option for the Stratix and
Stratix GX devices.
Figure 5–16 shows the Programmer after you have done these steps.
Figure 5–16. Quartus II Programmer for the Stratix GX-to-Stratix Bridge Test
4.
Click Start to configure both devices. When configuration is
complete for both devices, the GX_CONF_DONE (D7) and
S_CONF_DONE (D6) LEDs illuminate.