beautypg.com

Run the stratix gx hm-zd spi-4.2 loopback test – Altera High-Speed Development Kit, Stratix GX Edition User Manual

Page 37

background image

Altera Corporation

Quartus II Version 3.0

4–9

Run the Preloaded Diagnostic Tests

Stratix GX HM-Zd SPI-4.2 Loopback

Figure 4–5. Install the HM-Zd SPI-4.2 Loopback Cards

4.

Supply power to the board.

5.

Confirm that the Stratix GX device has finished configuration (the
GX_CONF_DONE (D7) LED illuminates).

Run the Stratix GX HM-Zd SPI-4.2 Loopback Test

Perform the following steps to run the test.

1.

Setthe Stratix GX dipswitch 5 to 1 (up position).

2.

Press the reset pushbutton switch (GX_CLR).

3.

Press the start pushbutton switch (Stratix_GX_PB_0). Several LEDs
illuminate.

LED0 is the high-speed data match LED. If it illuminates, the test
is successful.

LED1 indicates that the GX device has received the data.