No] rpr-ieee shutdown {east | west – Cisco 15327 User Manual
Page 501

A-27
Ethernet Card Software Feature and Configuration Guide, R7.2
Appendix A Command Reference
[no] rpr-ieee shutdown {east | west}
[no] rpr-ieee shutdown {east | west}
This command is similar to a rpr-ieee protection request forced-switch {east | west} command on the
span. This command is essentially no different in function; it is an easier way to do the same thing.
Syntax Description
Defaults
Default is no shutdown.
Command Modes
IEEE 802.17b based RPR interface configuration
Usage Guidelines
Functionally, there is no difference between this command and the protection request commands.
In this command, shutdown can be shortened to shut.
Note
This command cannot be cleared by transitioning the span state from OOS,DSBLD (Locked,disabled)
to IS/IS,AINS/OOS,MT (Unlocked,enabled,automaticInService or Locked,maintenance).
Examples
In this example, interface is shortened to int.
Router(config)# int rpr-ieee 0
Router(config-if)# rpr-ieee shut east
Related Commands
None
Parameter
Description
east
Specifies a shutdown on the east span of the interface.
west
Specifies a shutdown on the west span of the interface.