Rpr-ieee protection timer slow rate {east | west – Cisco 15327 User Manual
Page 494

A-20
Ethernet Card Software Feature and Configuration Guide, R7.2
Appendix A Command Reference
rpr-ieee protection timer slow rate {east | west}
rpr-ieee protection timer slow rate {east | west}
Use this command to configure the slow protection timer value on the specified
IEEE 802.17b based RPR span.
Syntax Description
Defaults
N/A
Command Modes
IEEE 802.17b based RPR interface configuration
Usage Guidelines
This value determines the sending rate of protection messages between protection events.
In this command, protection can be shortened to prot.
Examples
In this example, interface is shortened to int.
Router(config)# int rpr-ieee 0
Router(config-if)# rpr-ieee prot timer slow 2 east
Related Commands
rpr-ieee protection timer fast
Parameter
Description
east
Pertains to configuration for eastbound span traffic.
west
Pertains to configuration for westbound span traffic.
rate
The rate, expressed in milliseconds, at which the slow protection timer
sends a protection message. This occurs after a protection event on a
particular (east or west) span. The rate is stated in 100-millisecond
increments, with a value of 1 to 10. For example, a rate of 2 would be
equivalent to 200 milliseconds.