Rpr-ieee keepalive-timer interval [east | west – Cisco 15327 User Manual
Page 488

A-14
Ethernet Card Software Feature and Configuration Guide, R7.2
Appendix A Command Reference
rpr-ieee keepalive-timer interval [east | west]
rpr-ieee keepalive-timer interval [east | west]
Use this command to configure the keepalive timer configuration on a specific IEEE 802.17b based RPR
span (east or west).
Syntax Description
Defaults
The default is 1 second.
Command Modes
IEEE 802.17b based RPR interface configuration
Usage Guidelines
If a station does not receive fairness frames from its neighboring stations in the ring, the keepalive timer
value determines how much time will elapse before a protection event is triggered. The keepalive timer
works in tandem with the SONET holdoff timer. You would lengthen both of these timer intervals to
avoid double hits when IEEE 802.17b based RPR is running over a SONET-protected network.
Examples
In this example, interface is shortened to int.
router(config)# int rpr-ieee 0
Router(config-if)# rpr-ieee keepalive-timer 100 east
Related Commands
rpr-ieee protection sonet holdoff-timer
Parameter
Description
east
Pertains to configuration for eastbound span traffic.
west
Pertains to configuration for westbound span traffic.
interval
Timer interval expressed in milliseconds. Protection switch keepalive range
from 0 to 200 milliseconds.