9.1.1
Standard Doors/Gates Properties
Click on Setup > System > Properties (tab) > Doors/Gates.
Each door must be assigned a property set. There are 4 standard property sets that cannot be modified.
However, if these do not fit the necessary requirements, new property sets may be created.
Use the following table to determine whether one of the standard property sets may be used.
Standard 4
Door
Standard 2
Door
Extended 4
Door
Extended 2
Door
Door Type
Standard
Standard
Standard
Standard
Auto Unlock/Lock Timezone
Never
Never
Never
Never
Unlock Time
10
10
10
10
Extended Unlock Time
20
20
20
20
Open Time
10
10
10
10
Extended Open Time
20
20
20
20
First Person In
Not Used
Not Used
Not Used
Not Used
Request To Exit (RTE) 1
Momentary
Unlock
Momentary
Unlock
Momentary
Unlock
Momentary
Unlock
Request To Exit (RTE) 2
Not Used
Not Used
Not Used
Not Used
Door Lock Relay Active
Energized
Energized
Energized
Energized
Door Forced Relay Active
Not Used
Not Used
Energized
Energized
Door Held Relay Active
Not Used
Not Used
Energized
Energized
Alarm Shunt Relay Active
Not Used
Not Used
Energized
Energized
Door Switch Contact Type
Normally
Closed
Normally
Closed
Normally
Open
Normally
Open
Door Switch Circuit Type
None (2 State) None (2 State) None (2 State) None (2 State)
Request To Exit 1 Contact
Type
Normally
Open
Normally
Open
Normally
Open
Normally
Open
Request To Exit 1 Input
Circuit Type
None (2 State) None (2 State) None (2 State) None (2 State)
Request To Exit 2 Contact
Type
Not Used
Not Used
Normally
Open
Normally
Open
Request To Exit 2 Circuit Type None (2 State) None (2 State) None (2 State) None (2 State)
Latch Integrity Contact Type
Not Used
Not Used
Normally
Closed
Normally
Closed
Latch Integrity Circuit Type
None (2 State) None (2 State) None (2 State) None (2 State)