Meter adjustment parameters, Cr-.on meter adjustment parameters – Toshiba Tosvert VF-A5 User Manual

Page 95

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

U r .

R H

(AM/FM Adjustment Parameters)

F R S L . R R 5 L
F R

H R

Meter adjustment parameters

Related parameters

F P 5 L

FM terminal function selection

R P 5 L

F P

Frequency meter adjustment

R P

AM terminal function selection

Current meter adjustment

A frequency meter or current meter can be connected to the unit and configured according to the

and

F H S L

R P 5 L settings,

* The output signal from the FM (AM) terminal is a 0-1 mAdc, 0-7.5Vdc analog signal.

Use a 1 mAdc full-scale ammeter or 7.5Vdc-1 mA full-scale voltmeter.

The meter’s zero point should be adjusted with the meter’s adjusting screw. Calibrate the scale with | F O

or

R P

★ The max. scale of the ammeter should be at least 2.5 times the inverter’s rated output current.

F P 5 L

setting value

R P 5 L

Function

Default gain

(full-scale level)

0

Pre-compensation reference frequency

F H

1

Post-compensation output frequency

F H

S

Frequency setting value

F H

3

Output current

130%

H

DC voltage Note)

260V (400V class is 520V)

5

Output voltage

260V (400V class is 520V)

B

Torque current

130%

n

Excitation current

130%

B

PID feedback value

F H

g

Motor overload ratio

100%

ID

Inverter overload ratio

100%

/ I

DBR overload ratio

100%

1 3

Input power

130% of (V^

X

200 or

400V

X

rated current)

¡ 3

Output power

130%of(VsT

X

200 or

400V

X

rated current)

Note) If

F P 5 L

(or

R P 5 L

) is set to 4 (DC voltage), a DC voltage that is less than approx. 50%

of the rated voltage cannot be measured. Also, if main circuit power is OFF

{ P D F F

displayed), an

approx. 50% bias amount will be constantly output.

- 89 -