Panel feedback control, Panel reset selection, P f b – Toshiba Tosvert VF-A5 User Manual
Page 59: P r e 5
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
u r
P j (Panel Control Parameters)
P F b
r
Panel feedback control
This is used when
G r . F b
feedback parameters are used.
* If no feedback control is selected with the C»~.
F b
feedback control selection parameter
j F b P I
feedback control will not occur even if panel feedback control ON (
P F b C
= D) is selected.
★ Refer to the section on C r. F b for feedback control.
P r E 5
Panel reset selection
The trip causes that can be reset when the inverter trips as a result of a failure or fault, etc., can be selected.
P r E 5
setting value
Function
D
All possible
1
Only OL can be reset
3
Only OL, 001, 0C2, and 0C3 can be reset
★ The trip cause must be removed before the inverter is reset, or the inverter will trip again.
OL indicates
D L - i n , D L
-
l i b
, and
O L r
. Resetting is not possible during the required cooling
time after tripping. The inverter can be reset, however, by turning the control power OFF.
Required cooling time under standard settings
D L
-
I n
: Approx. 1 min.
D L
-
f i b
: Approx. 5 min.
D L r
: Approx. 30 sec.
53 -