6. standard Connections

Refer to the operation selection expianation (7.4 Operation mode seiection, page 40), and parameter list
(page 105).

6.1 Standard Connection Example

Example 1 To set run frequency, forward/reverse run, and decelerated stop via the panel.

3-phase main circuit
power source

In standard configuration, F)0 and SO
are connected with jumpers to the main
circuit terminals. (Only for 30kW and smaller)

(Refer to page 18.)

Setting

Operating frequency setting

via the panel

These are jumpered at shipment.

Parameter group

Parameter

Setting value

Reference page

Gi-.Ut

C no d (Command mode selection)

Bci H №••

40

C r-.U k

F nOd (Frequency setting mode

selection)

2 o r H Notes)

40

Note 1)

rrwod:

rrwj'B:

set to B ... Press RUN to start running,

set to H ... Press PANEUREMOTE , then

RUN

to start running.

* Refer to page 28 '7.2 Basic Operation* for the operation methods.

Note 2) I F n n rl I set to B ... The reference frequency can be set only from the operation panel.

Setting

Parameter group

Parameter

Setting value

Reference page

Or-.ut

C nod (Command mode selection)

1 OT H Not»3)

40

0 r.U k

F nod (Frequency setting mode

selection)

B

40

twice.

Note 3) Emergency stop is possible from the panel by pressing STOP

I r n n H 1 set to / ... Running from operation panel is not possible.

I r n n r/1 set to M ... Press rPANELVREMOTE , and running is possible from the

operation panel by pressing

RUN