Command/frequency mode selections

Related parameters

C f l O d Command mode selection

F n O d Frequency setting mode selection

E f l O d

and

F i l D d

select the terminal, panel and option inputs.

E n o d , F i l D d setting value

Function

0

Only RS232C input valid

1

Terminal input valid

d

Panel input valid

3

Communication option board input valid

4

Ali valid

Note)

RS232C input is

always valid.

★ The priority when set to 4 is as follows:

1.

RS232C communication

2.

Panel (select with PANEU/REMOTE key)

3.

Terminal block (when selected by the user) Note)

4.

Communication option board

5.

Terminal block (normal)

Note) When 3 9 (panel/terminal mode selection) is allocated to a terminal with the input terminal selection

function.

When the switching signal is not input to the terminal, terminal block mode is selected.

The following three types of contact terminal inputs are always valid regardless of the

I

L f l D d

and

I

F f l D d

I

settings.

(Seep.55 C»-.5t f

f t *

I (*•• 0

~ /0 )•)

Setting value

Function

E

RES (fault reset)

1

ST (gate ON/OFF)

I D

Emergency stop

E n P d l

and

I F nOd~\

can be changed while running, but the new settings wiil not become valid until

the motor has stopped once (O.OOHz). (Always stop once after changing

j E H D

dl or |

F i l D d I.)

-

86

-