Jogging operation
Related parameters
Jog run frequency
J D O
J 5 b P Jog stop control
A jog run can be started and stopped with the F, R terminal signals by setting the jog run frequency
I
J D O
I
. (Refer to the section on
O r . 5 1
I
I h * I
for allocating the input terminals.)
* Short circuit JOG-CC before starting a jog run.
A)
Jog forward run
B)
Jog reverse run
C)
Runs at the operating frequency set from the panel or terminal block when JOG-CC is opened.
* Jogging will not occur if JOG-CC is shorted while running.
* When using JOG run and preset speed run modes simultaneously, the preset speed run mode will have
priority. (For example, if the preset speed run mode is set for reverse run, the preset speed is selected by
SS1-SS4, and then a JOG operation is performed, the motor will jog in reverse.)
Select the jog stop method with I iJ 5 Pi .
Set the jog run frequency to a value other than 0 to execute a jog run.
JSfcP setting
Function
D
Decelerated stop (Decelerated stop according to the I H t L Tl parameter.)
/
Coast-stop
DC injection braking stop (Stop according to DC braking parameters set by
I
dbF I
LdbL.I I
dbfc I )
The jog run acceleration time is set to zero, so setting the JOG run frequency to 5Hz or less is
recommended. If set higher, overcurrent trips may occur, or the motor may not rotate smoothly.
Note) During a jog operation, the LOW and RCH signals will not be output, and PID control will not be
enabled.