u r

5 Izi

Selection Parameters)

I t

Input terminal selections ©

t o

I t I D

Related parameters

I t

I t D

I t I I

I t 1 0

Input terminal selection

Input terminal function selections

Potential terminal function selection
(Allocated to a function to always be ON.)

Parameter

IkO

It I

I k S

It3

It 4

Its

Its

ItT

ItB

JM

It ID

Jt 11

Input terminal

R

S1

S2

S3

S4

F

RES

ST

S5

S6

S7

Potential terminal

I t D

to

I t I I according to the data

The input terminal functions can be changed by setting

in the following table.
Note 1) Input terminals S5, S6 and S7 are added with the expansion terminal block PCS (optional).
Note 2) If the same setting value is assigned to more than 1 input terminal function, *OR’ logic is in effect.

Note 3) To turn each terminal ON/OFF, open/close each terminal-CC (closed=ON, open=OFF).

Setting

value

Valid

code

Function

Setting

value

Valid

code

Function

D

C

R (reverse run)

B E

F

Binary bit #4

1

C

SS1 (15 preset speed selection)

B n

F

Binary bit #5

5

c

SS2 (15 preset speed selection)

B B

F

Binary bit #6

B

c

SS3 (15 preset speed selection)

B 9

F

Binary bit #7

H

c

SS4 (15 preset speed selection)

3 0

F

Binary bit #8

5

c

F (forward run)

3 1

F

Binary bit #9

B

A

RES (fault reset)

3 B

F

Binary bit #10

n

A

ST (gate ON/OFF)

3 3

A

Ignore terminal input

B

C

JOG selection

3 9

F

Up/Down frequency setting (UP)

9

C

AD2 selection

3 5

F

Up/Down frequency setting(DOWN)

1 0

A

Emergency stop

3 E

F

Frequency clear

1 1

C

DC injection braking ON/OFF

3 1

C

PUSH-type RUN key

I B

C

Fundamental parameter switching

3 B

C

PUSH-type STOP key

(V/F #2)

3 9

A

Panel/terminal mode selection

1 3

C

PID control ON/OFF

9 0

C

Forward/reverse run selection

1 9

C

Pattern run selection #1

9 1

C

RUN

I S

C

Pattern run selection #2

9 B

F

Binary data write

I E

C

Pattern run selection #3

9 3

P

PNUREMOTE key

i n

C

Pattern run selection #4

9 9

P

MON key

I B

C

Pattern run continue signal

9 5

P

PRG key

1 9

Note

Pattern run step trigger signal

9 E

P

UP (A) key

B O

C

JOG forward run

9 1

P

DOWN (V) key

B 1

C

JOG reverse run

9 B

P

ENTER key

B B

F

Binary bit #0

9 9

P

RUN key

B 3

F

Binary bit #1

5 0

P

STOP key

B H

F

Binary bit #2

5 1

C

Commercial power/INV switching

B 5

F

Binary bit #3

signal

- 55 -