Error Messages

- Setup software TM-H1 TM-Navigator User’s Manual -

Error Messages

This section explains information about the displayed error messages that appear when an error occurs.

Item

Display contents

Remedy

Reference

page

File operations Failed to read the file ( ).

Verify that the correct file is set.

* The path name is entered in the

parentheses ( ).

Check whether the selected file is an TM-

Navigator program file (*.prs) or an

environment setting file (*.ens).

3-2

Failed to read the environment settings.

( )

* The failed item is entered in the parentheses ( ).

Check the unreadable environment setting

items and set correctly on the controller.

3-3

Master image is short. Change short master

image for non-reg.

This occurs when the master image saved

during program saving does not exist in the

same folder as for the selected file.

Put the master image (.bmp) in the same

folder.

5-6

Sending and

receiving

settings

Communication failed.

Set the controller to "Measurement screen

(during measurement)".

-

Transfer setting failed.

• Check whether communication is possible

between the controller and computer.

• Set the controller to "Measurement screen

(during measurement)".

3-4

Receive settings failed.

• Check whether communication is possible

between the controller and computer.

• Set the controller to "Measurement screen

(during measurement)".

3-4

Head setting

Image capture failed.

Perform "Trigger input" with the controller to

capture the image.

5-3

The threshold exceeds the setting range. Set

the value between 10 and 99.

Set the threshold within the displayed range.

5-3

Master

registration

The master image is not registered and

cannot be set. Register the master image in

"Master Image registration".

Register the master image.

5-6

Correction angle is over the setting range.

Set the correction angle to within ±20

q.

5-8

Position

correction

The correlation value exceeds the setting

range.

Set the correlation value within the setting

range.

5-9

Measurement

setting

The master image is not registered and

cannot be set. Register the master image in

"Master Image registration".

This is displayed when the master image is

not registered when "Search" is selected in

"Measurement type".

Register the "Master image".

5-10