4-20
- Setup software TM-H1 TM-Navigator User’s Manual -
Image Storage
Displa
ying
the
Measurem
ent Data
(1) [Start image storage] button
Starts storing the image data from the controller.
(2) [Stop storage] button
Stops storing the image data from the controller.
(3) [Clear storage data] button
Clears all of the image data that is stored in the internal memory of the controller.
(4) [Re-measure (Ref.Value)] button
This function changes or confirms the measurement settings using saved images.
The confirmed setting conditions can be saved and sent to the controller.
"Functions and Usage of Re-measure (Ref.Value)" (page 4-10)
(5) [Help:Ref.Value] button
The help file for Re-measure (Ref.Value) is displayed.
(6) [Image storage] button
Displays the [Image storage] dialog box.
This dialog box can be used to configure the controller's image storage settings.
"Changing the image storage settings" (page 4-22)
(7) Num. of image
Displays the number of images that are stored on the controller.
(8) Current status
Displays the storage status (Storing / Stopped)
(9) Image No.
Displays the number of images and selects the image No. that is displayed on the view image area.
(10)Acquisition Date
Displays the date and time when the image selected for (9) Image No. was stored on the controller.
(11)[Delete Image] button
Deletes the displayed image data.
(12)[Read storage data] button
Reads the image data in the connected controller on TM-Navigator.