Help:ref.value, How to set re-measure (ref.value) – KEYENCE TM-3000 Series User Manual
Page 33
4-11
Displa
ying
the
Measurem
ent Data
- Setup software TM-H1 TM-Navigator User’s Manual -
View Image
Help:Ref.Value
The Re-measure (Ref.Value) function of TM-Navigator
displays the measurement result (Re-measure
(Ref.Value)) by using the measurement image obtained
from the head and head data to make adjustments. The
head data to be used is saved on the hard disk drive in
the computer and is changed according to the following
conditions.
• When receiving the settings from the controller:
The head data for the connected head is overwritten
and saved.
• When selecting "Head Select":
The initial data in TM-Navigator is overwritten and
saved.
In the following cases, the measurement result by Re-
measure may differ from the actual measurement value
by the controller. In these cases, use the Re-measure
value as a reference value.
• When the head that measured the image for Re-
measure is different from the head that obtained the
head data saved on the computer
• When the head data is the initial data in TM-Navigator
To match the Re-measure value with the actual value
measured by the controller, receive the settings from the
controller before re-measurement.
Reference
The following contents will not be reflected in the Re-
measure value.
• Auto-zero
• Average (Always set to 1.)
How to Set Re-measure (Ref.Value)
This section describes how to set the area for "OUT
meas" and "Element".
For more information on each item, see "TM-3000 Series
User's Manual".
1
Display the [View Image] window.
2
Click the [Start image capturing] button.
Load the image from the controller to display.
3
Click the [Stop image capturing] button.
Image capturing stops.
4
Click the [Re-measure (Ref.Value)] button.
The display shows that the [Re-measure (Ref.Value)]
button is pressed down, and "OUT meas" and
"Element" are displayed.
5
Press the "OUT meas" or "Element" tab
to select the number to set and make
the settings for each item.
The master registration image is displayed on the
view image area, and the measurement result is
updated and displayed.
The Re-measure result using the master image is displayed
as a reference value according to the setting contents.
Clicking [OK] button enables the setting contents
and the Re-measure (Ref.Value) is displayed. If this
is not needed, cancel it.
6
Click the [Reflect to setting] button on
the [View Image] window.
The contents set for "OUT meas" or "Element" are
reflected in TM Navigator software and not in the
controller.
7
To reflect the settings in the controller,
click the [Send settings to controller]
button on the main window.
OK / Cancel
Reference value