View Image

Help:Ref.Value

The Re-measure (Ref.Value) function of TM-Navigator

displays the measurement result (Re-measure

(Ref.Value)) by using the measurement image obtained

from the head and head data to make adjustments. The

head data to be used is saved on the hard disk drive in

the computer and is changed according to the following

conditions.
• When receiving the settings from the controller:

The head data for the connected head is overwritten

and saved.

• When selecting "Head Select":

The initial data in TM-Navigator is overwritten and

saved.

In the following cases, the measurement result by Re-

measure may differ from the actual measurement value

by the controller. In these cases, use the Re-measure

value as a reference value.
• When the head that measured the image for Re-

measure is different from the head that obtained the

head data saved on the computer

• When the head data is the initial data in TM-Navigator

To match the Re-measure value with the actual value

measured by the controller, receive the settings from the

controller before re-measurement.

Reference

The following contents will not be reflected in the Re-

measure value.
• Auto-zero
• Average (Always set to 1.)

How to Set Re-measure (Ref.Value)

This section describes how to set the area for "OUT

meas" and "Element".

For more information on each item, see "TM-3000 Series

User's Manual".

1

Display the [View Image] window.

2

Click the [Start image capturing] button.

Load the image from the controller to display.

3

Click the [Stop image capturing] button.

Image capturing stops.

4

Click the [Re-measure (Ref.Value)] button.

The display shows that the [Re-measure (Ref.Value)]

button is pressed down, and "OUT meas" and

"Element" are displayed.

5

Press the "OUT meas" or "Element" tab

to select the number to set and make

the settings for each item.

The master registration image is displayed on the

view image area, and the measurement result is

updated and displayed.

The Re-measure result using the master image is displayed

as a reference value according to the setting contents.

Clicking [OK] button enables the setting contents

and the Re-measure (Ref.Value) is displayed. If this

is not needed, cancel it.

6

Click the [Reflect to setting] button on

the [View Image] window.

The contents set for "OUT meas" or "Element" are

reflected in TM Navigator software and not in the

controller.

7

To reflect the settings in the controller,

click the [Send settings to controller]

button on the main window.

OK / Cancel

Reference value