beautypg.com

KEYENCE TM-3000 Series User Manual

Page 59

background image

5-13

Set

tin

g Each

Fu

nct

ion

Setting Items

- Setup software TM-H1 TM-Navigator User’s Manual -

Scaling

The displayed value for the measurement value can be scaled (calibrated) as desired.

„ Scaling setting screen

1

When the [Scaling settings] button is clicked, the following setting screen appears.

2

Click the [Acquire measure] button.

The setting values on TM-Navigator are sent to the controller and the measurement value is acquired.

Setting items

Description

(1)

Acquire measure

This acquires the measurement value from the controller. The value is updated

each time this button is clicked.

(2)

Measurement value

This displays the acquired measurement value.

(3)

Trigger input

The trigger is input as an external trigger.

(4)

Measure

oInput 1 /

Measure

oInput 2

This sets the acquired measurement value as Input value 1 or Input value 2.

(5)

Input value 1 / Input value 2

This sets the input value.

(6)

OK

This confirms the set contents and closes the window.

(7)

Display value 1 / Display value 2 This sets the display value corresponding to the input value.

(8)

Cancel

This cancels the set contents and closes the window.

(3)

(1)

(2)

(4)

(5)