Page 164

MAINTENANCE INTERVALS
158
2.
Remove the spark plugs with a 5/8” spark plug
socket. See Figure 9.2.
3.
Clean the Spark plugs with carburetor cleaner or
replace them with two Champion RC12YC spark
plugs.
NOTE: Do not clean the spark plugs mechani-
cally (sand blasting or scraping). This will dam-
age the insulator.
4.
Gap the electrodes to .030” (.76mm).
5.
Thread the spark plugs into the spark plug holes.
6.
Tighten the spark plugs to a torque of 18-22 ft -
lbs (24.4 - 29.8Nm).
NOTE: Refer to Kohler manual TP-2574 for
more detailed instructions.
7.
Push the spark plug wires onto the spark plugs
until they snap into place.
Air filter and foam pre cleaner
A dirty air filter and/or foam pre cleaner can reduce
engine power, increase fuel consumption and make
starting more difficult.
The foam pre cleaner should be checked before
each use and cleaned every 25 hours.
The air filter should be cleaned before each use
and replaced every two months or 50 hours of use.
To check the air filter and pre cleaner:
1.
Swing open the air filter door located at the front
of the engine. See Figure 9.3.
2.
Lift up the wire retainer. See Figure 9.4.
Figure 9.2
5/8” socket
Figure 9.3
Air filter door
Figure 9.4
Wire retainer