2 display menu - configuration, Display menu - configuration – Pilz PNOZ s30 24-240VACDC 2 n/o 2 n/c User Manual
Page 38

Commissioning
Operating Manual PNOZ s30
1001715-EN-13
38
EMC-compliant wiring for connecting 2 proximity switches
Shielded
Connection Box
Power Supply
0 V DC
24V DC
PE
L1
L2
U
B
A
B
C
D
E
Cabinet
RJ45
A
/A
B
/B
Z
/Z
GND
S
IN2
IN1
GND
INI_A
INI_B
To avoid EMC interference we recommend that the shield on the encoder cables or the
housing of the shielded junction box is only connected to earth at a single point:
A
or B or C or D or E
Conductor loops outside the shield must be avoided.
If a shielded junction box is not used, the shield must run continuously from the encoder to
the evaluation device.
Display menu - Configuration
The menu settings are made on the unit's display via a rotary knob. You have the option to
make the settings on the knob by hand or with a screwdriver. If you make the settings with
a screwdriver, the knob can remain within the unit.
6.2