Pilz PNOZ s30 24-240VACDC 2 n/o 2 n/c User Manual
Page 24

Function description
Operating Manual PNOZ s30
1001715-EN-13
24
The following basic configurations are available:
Basic configuration 1: Ini pnp pnp (proximity switch)
Pre-defined settings and configuration options:
}
Encoder type
2 pnp type proximity switches
}
Switch functions
–
Standstill (F1)
– Standstill frequency configurable in Hz
–
Speed (F2)
– Max. frequency (v max) configurable in Hz
}
Parameter set/select input
P0, select inputs are ignored ("None" mode")
}
Hysteresis
Standstill and speed, 2 % each
}
Output assignment
– Standstill: Relay output Rel. 1 and semiconductor output Out 1
– Speed: Relay output Rel. 2 and semiconductor output Out 2
}
Reset mode
– Rel. 1, Rel. 2 Out 1, Out 2: Automatic reset
}
Switch delay
None
}
Max. encoder frequency
3.5 kHz
Basic configuration 2: Rotary encoder
}
Encoder type
Rotary encoders
– Rotary encoder type configurable
}
Switch functions
–
Standstill (F1)
– Standstill frequency configurable in Hz
–
Speed (F2)
– Max. frequency (v max) configurable in Hz
–
Direction (F3)
Direction left
Tolerance for wrong direction = 10 Imp
–
Direction (F4)
Direction right
Tolerance for wrong direction = 10 Imp