Management Commands

AT8904M

AT8904M CLI Reference Manual

Page 6 - 34

6.12

Bootcycle commands

6.12.1

show boardinfo bootcycle

This command displays whether a bootcycle-detection is activated and (if activated)

the related parameters.

Format

show boardinfo bootcycle

Mode

Priviliged Exec

6.12.2

set board bootcycle

This command activates/deactivates a bootcycle-detection and (if activated) sets the

related parameters. Parameter ‘none’ deactivates the bootcycle detection. Parameters

‘event’ and ‘pwr-down’ activate the bootcycle detection and execute an action if the

number of , checked in seconds, is reached. The executed action is

the generation of an event and additionally for ‘pwr-down’ switch off the Power-PC.

Format

s

et board bootcycle none

set board bootcycle event

set board bootcycle pwr-down

Mode

Priviliged Exec

6.13

Watchdog support

The IPMC based hardware watchdog supervises board operation. There are 4 distinct

stages in the lifecycle of the system where different watchdog timers and actions are

used.

All watchdog parameters are stored in the bootloader environment. All times are in

seconds. All watchdog events will power cycle the board when the watchdog expires.

BIST watchdog during BIST

OS loader watchdog during loading of kernel and INITRD

Application Startup watchdog during startup of switching application

Application Running watchdog during normal execution of switching application

6.13.1

set watchdog

This command configures the watchdog. It sets the timeout for different watchdog

(during BIST, during loading of kernel and INITRD, during startup of switching

application and during normal execution of switching application) and the heartbeat

(sending interval and number of missed heartbeats before failure occurance). All

values (except missed heartbeats) are in seconds, a value “0” means that the related

watchdog is disabled.

Default

disabled (0)

Format

set watchdog bist

<0,30-6000>

set watchdog osloader

<0,120-6000>

set watchdog init

<0,60-6000>

set watchdog application

<0,5-6000>

set watchdog heartbeat

<0,1-6000>