10 show serviceport, 2 console port access commands, 1 configuration – Kontron AT8904 CLI User Manual
Page 259: 10 show serviceport - 5, 2 console port access commands - 5, Configuration - 5, At8904m management commands
AT8904M
Management Commands
Page 6 - 5
AT8904M CLI Reference Manual
IP Address
The IP address of the interface. The factory default value is 0.0.0.0
Subnet Mask
The IP subnet mask for this interface. The factory default value is
0.0.0.0
Default Gateway
The default gateway for this IP interface. The factory default value
is 0.0.0.0
Burned In MAC Address
The burned in MAC address used for in-band connectivity.
Locally Administered MAC Address
If desired, a locally administered MAC address
can be configured for in-band connectivity. To take effect, 'MAC
Address Type' must be set to 'Locally Administered'. Enter the address
as twelve hexadecimal digits (6 bytes) with a colon between each byte.
Bit 1 of byte 0 must be set to a 1 and bit 0 to a 0, i.e. byte 0 should
have the following mask 'xxxx xx10'. The MAC address used by this
bridge when it must be referred to in a unique fashion. It is recom-
mended that this be the numerically smallest MAC address of all ports
that belong to this bridge. However it is only required to be unique.
When concatenated with dot1dStpPriority a unique BridgeIdentifier is
formed which is used in the Spanning Tree Protocol.
MAC Address Type
The MAC address should be used for in-band connectivity. The
choices are the burned in or the Locally Administered address. The
factory default is to use the burned in MAC address.
Network Configuration Protocol Current
The network protocol is being used. The
options are bootp | dhcp | none.
6.1.10
show serviceport
This command displays service port configuration information.
Format
show serviceport
Mode
Privileged EXEC
IP Address
The IP address of the interface. The factory default value is 0.0.0.0
Subnet Mask
The IP subnet mask for this interface. The factory default value is
0.0.0.0
Default Gateway
The default gateway for this IP interface. The factory default value
is 0.0.0.0
ServPort Configuration Protocol Current
The network protocol used on the last, or
current power-up cycle, if any.
Burned in MAC Address
The burned in MAC address used for in-band connectivity.
6.2
Console Port Access Commands
This section describes the commands you use to configure the console port. You can
use a serial cable to connect a management host directly to the console port of the
switch.
6.2.1
configuration
This command gives you access to the Global Config mode. From the Global Config
mode, you can configure a variety of system settings, including user accounts. From