3.4.9 Testing the Buttons

This function will allow you to test the four wash buttons and the change button. The following
steps will assist in testing the buttons.

1.

Place the WSII in Setup mode. Scroll to: Diagnostics (*) Test Buttons (*)

2.

Press each button one at a time. As you press each button, the main display
should show the wash number that each button corresponds to (1-4) and a “C”
when the change button is pressed.

3.4.10

Test Exp. Memory

An expansion memory chip will be located at connector U57 on the CPU board. To ensure
that the expansion memory is working properly, follow the steps below.

1.

Place the WSII in Setup mode. Scroll to: Diagnostics (*) Test EXP. Memory" (*)

2.

“PASSED” or “FAILED” will appear in the main display window depending on the
outcome of the test.

3.4.11

Test RFID (AWID)

To ensure the ReachFree ID system is reading the tags properly. Once the reader
antenna is installed and vehicle tag is detected by the reader, the 8-digit code will be
displayed in the third window on the Wash Select II door. As long as the RF tag remains
in range of the reader, the WSII will beep once per second. You can determine the area
the RF Reader can read tags by moving the tag around and listening for the beeps. As
long as the unit is beeping once per second, the RF tag is in-range.

The Diagnostics>Test RFID (AWID) function also has a power adjustment. All RFID boards
are shipped with the power adjustment set to 5. If you need to adjust the power for the
reader, enter a number from 1-9 on the keypad. The power levels range from 1 to 9, with 9
being the highest.

3.4.12 Inapplicable

Diagnostics with WashPay Integration

When the Wash Select II is integrated with the WashPay site server, The following
diagnostics are no longer applicable:

• Testing the Modem

• Get Network Info

• Modem Loop back

• POS/485 Loop back