12 remote code pos4000 support, 1 enable and setup remote code, Remote code pos4000 support – Unitec Wash Select II With WashPay Integration Operations Manual User Manual
Page 32

W A S H
S E L E C T
I I
Document Number:
WS21058
20
Document Title:
WSII Operations Manual ver 6.10
The Optioning feature is highly configurable and a separate menu is provided with all the
associated commands. This menu is located under the existing Wash Interface menu. In
addition, a new command under the Credit Menu called “Split Tender” (See Section 2.3.19)
controls whether a credit card can be used to purchase an option.
To enable Optioning:
1.
Place the WSII in Setup mode. Scroll to: Wash Interface (*) Optioning (*)
2.
Press the (1) button for “YES” to enable or the (3) button for “NO” to disable, and
then press the (*) key.
If you chose to enable Optioning, you will then need to set the Features, Option prices
and names. This task is accomplished on the WashPay server. For further instruction,
please see the Sierra Management Application Programming Manual at
2.5.12
Remote Code POS4000 Support
The Wash Select II may be configured to interface to a POS4000 in order to be activated by
codes sold at one or multiple POS4000 units. In cases where it is not feasible to wire the
POS4000 and WSII to each other, the Remote Code option may be used. This option allows
an encrypted wash code to be sold from the POS4000, then, once this code is entered into
the WSII, it is decrypted and the wash is fired.
For Remote Code functions, make sure washes and options programmed in the WashPay
server are same as ones programmed in the POS4000 or the code will be declined. For
example, a code sold with an option will not be accepted in a WSII with optioning disabled.
Also verify the date settings on the WSII and the POS4000 involved to make sure they are
accurate because the Remote Code function depends on them.
2 . 5 . 1 2 . 1 E n a b l e a n d S e t u p R e m o t e C o d e
Before starting using remote code, make sure these requirements are met: on the WSII:
• Expansion memory installed
• POS LINK is not set to POS4000 Link
To enable the Remote Code function in the WSII:
1. Place the WSII in Setup mode. Scroll to: Wash Interface (*) Remote Code (*)
2. “Use Remote Code?” will be displayed. Press (1) for yes and (3) for no. Press (*)
to enter.
Once enabled, go to Parameter Setup and enter the following information:
• IDs of POS Where Codes Sold: enter the ID of the POS4000(s) where the code is sold.
Up to 4 POS4000 IDs are supported. Default = 1