2.13.1 Interface
Mode
The interface mode configures the Wash Select II to listen and respond to POS4000
messages or to enable the Multi-Unit link. Once this mode is enabled, the Wash Select II will
respond to messages sent by the POS4000 or a master Wash Select II Unit. It will also allow
codes purchased at the master POS4000 or a master Wash Select II unit to be used at a
secondary Wash Select II at your site. If at any time this feature is disabled or the unit loses
communication, you will get a message on the POS4000 that indicates “Time Out From Unit
“X”. (The “X” denotes the number of the unit, bay or other POS4000 (if there is more than one
POS4000) unit that has lost communication.) To configure the interface mode, follow the
steps below.
1.
Place the WSII in Setup mode. Scroll to: POS4000 Link (*) Interface Mode (*)
2.
Press the (0) key for “ALONE” (just one Wash Select II), the (1) key for
“WS2/POS” (Wash Select II and POS4000 units) or the (2) key for “Multi-Unit
Link” (multiple Wash Select II units).
Default: 0
2.13.2 Notifications
You can have any notifications that are normally sent to the pager printed at the POS4000 as
well.
1.
Place the WSII in Setup mode. Scroll to: POS4000 Link (*) Notifications (*)
2.
Enable or disable print errors by selecting Yes or No, respectively.
2.13.3
Set Bay Address
2 . 1 3 . 3 . 1 S e t P O S 4 0 0 0 B a y A d d r e s s
The POS4000 network allows for up to four entry systems to be connected to the same
“Master” POS4000. Units are denoted by the network address. Entry systems units are
assigned bay addresses 2-5. Bay number one should be configured as bay address two
(default).
Note:
The Master POS4000 will always be network address one.
If you have a multi-bay system, you need to change the settings as follows:
Table 5. POS4000 Bay Numbering
Bay Number
Bay Address
1 2
(Default)
2 3