6.3 P4 Input/Output Tab
Use this tab to set t he functionality of the four programmable I/O connections.
You can select Trigger, Product Change, Remote Teach, and Discrete inputs
and outputs as eith NPN (current sourcing) or PNP (current sinking). Once
NPN or PNP is selected, all inputs and outpus are either NPN or PNP.
Inputs and Outputs
I/O 1 through 4 in the I/O column correspond to Pins 5 through 8 in the Pin # column.
I/O, Pin #,
Function
Options from the drop-down list are:
• General Input: Input to the sensor.
• General Ouput: Output from the sensor that can be selected in a Test tool.
• Pass: Active when the entire nspection passes.
• Fail: Active when the inspection fails.
• System Error: Active when a system error occurs.
• Ready: Active when the sensor is ready to accept another trigger.
• Product Select: Used in conjunction with Product Change to select inspection
locations at which to begin execution.
Select the state (open or closed) that the output will take when not active.
Normally
Open/Closed
• Normally Open: The output becomes active when the logic condition controlling
the output becomes True.
• Normally Closed: The output becomes inactive when the logic condition controlling
the output becomes True.
Output Delay is the time from a trigger to start an inspection until the Sensor output turns
ON. It is available only for general outputs.
Output Delay
Note: If processing time is longer than the output delay, the output will become
active immediately after the processing is finished.
This option is available only for the general outputs; the other outputs (Pass, Fail, System Error,
and Ready) are latched only.
Output
Duration
• Latched: Active until the condition changes.
• Time: Active for a specific length of time.