beautypg.com

Banner PresencePLUS BCR 1.3 Series User Manual

Page 57

background image

ACTION is an operation the user intends to perform on the OBJECT_IDENTIFIER. There are three possible
actions available:

• GET — used to retrieve information associated with the named object. This information can be a

Boolean value, and unsigned or signed number, a string or, for complex objects like the
Communications tool, a field-delimited record that includes other data types.

• SET — used to assign a value to a named object.
• EXEC — used to execute a pre-defined functional object or activity in the sensor. Activities may

take object identifiers as parameter qualifiers.

The table below identifies objects that are supported in the current RCC release, their identifiers, and the
corresponding actions that they will support. Items highlighted in bold are command keywords. Flag objects
are appended with the FLG suffix, status objects are appended with the STS suffix, and counters are appended
with the CNT suffix.

Comments

Optional
Qualifiers

Required
Qualifiers

Support
Actions

Object or
Activity
Identifier

System
Object,
Component,
or Activity

If no qualifiers
are specified, a

Timeout
(msec)

or

None

EXEC

TRIGGER

Trigger

30 second
timeout is used.

NOWAIT

By default, a 30
second timeout
is used.

Timeout
(msec)

or

Numeric
Inspection ID

EXEC

PRODCHANGE

Product
Change

NOWAIT

Reset either the
System Error

None

SYSERRFLG

or

EXEC

RESET

Counter or
Flag Reset

Flag, Pass and

PASSFAILCNT

Fail counters, or

or

Missing Trigger
count.

MISSTRIGCNT

Enables remote
teach. If no

TRIGGER or
TRIGGER

None

EXEC

RTEACH

Remote Teach

qualifiers are

NOWAIT or

specified,

TRIGGER

remote teach

Timeout
(msec)

will occur on the
next trigger. If
TRIGGER
qualifier is
specified,
remote teach
will occur

57

Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com

Tel: 763.544.3164

P/N 000000

System Setup Window Overview

7/2009

This manual is related to the following products: