Read Acceptance

There are three levels of Read Acceptance, Loose (default), Medium, and Strict. Which you select will
determine how forgiving the Sensor will be regarding character variability. In other words, the stricter you set
Read Acceptance, the less forgiving the Sensor will be for variability, which might mean training more characters
that will lead to a bigger library, and eventually some effect on performance. Also, a Font Library that gets too
many characters may have an increased chance of false positive reads.

Note: No matter the level Read Acceptance selected, the software always uses a slightly tighter tolerance
when training the Sensor than when the Sensor is in Run mode.

Training List

You can add, load, or import images as a Training List to train character patterns into the Sensor.