beautypg.com

Banner PresencePLUS BCR 1.3 Series User Manual

Page 42

background image

Number of INS files
without Reference
Images*

Number of INS Files

INS Storage Memory

Sensor Type

999

160

64MB

Pro II Color

500+

150

8MB

Area/GEO/Edge

999

85

32MB

OMNI

999

72

32MB

OMNI Color

999

44

64MB

Pro II 1.3

999

44

64MB

OMNI 1.3

400+

8

BCR

999

20

32

GEO/Edge/Area/BCR 1.3

*Not saving a reference image with the inspection frees up a lot of room onboard the sensor. However,
inspections that include any of the following tools require a reference image to be saved:

• Geometric Find
• Geometric Count
• Pattern Find
• Pattern Count
• Color Match
• Color BLOB

5.4.3 Opening an Inspection from the Sensor or a Library

Inspections can be stored on the sensor or to a libary of inspections stored on a PC or network drive. To select
and open an inspection from the sensor or a library:

1. Click the Load tab.
2. From the Load from drop-down list, select the Sensor or a location on a PC or Network.
3. Select the desired inspection.
4. Click the Load button.

The tools from the selected inspection populate the Navigation/Results window. At this point, all tools in the
inspection can be modified. If new tools are to be added, simply select the tool in the Tool screen. If tools are
to be deleted, select the tool and click the Delete icon.

Note: If you want to see the the image stored with the inspection, check the Load reference
image
box.

P/N 000000

Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com

Tel: 763.544.3164

42

7/2009

Tools Screen

This manual is related to the following products: