1 trigger settings – Banner PresencePLUS BCR 1.3 Series User Manual
Page 33
4.4.1 Trigger Settings
Description
Field
Sets the sequence of valid triggers. If set to 1, an image is captured in response
to every valid trigger; if set to 2, and image is captured in response to every second
valid trigger, and so on.
Trigger Divide (range:
1-10,000 triggers)
Fixed time (ms) from the instant the Sensor receives a valid trigger to the instant
the Sensor captures the image.
Trigger Delay (range:
0-8,000 ms)
Eliminates unwanted triggers by accepting triggers only if they are above a
specified duration.
Minimum Trigger Width
(range: 1-8,000 ms)
Choose Leading Edge to capture images at the leading edge of a trigger signal.
Choose Trailing Edge to capture images at the trailing edge of the trigger signal.