beautypg.com

Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 85

background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

85

Connecting the Kinetix 5500 Drive System

Chapter 5

Figure 50 - 14 and 10 AWG Cable Installation

When the drive/motor combination calls for 14 or 10 AWG cable, the
feedback cable routes along with the power and brake wiring.

2. Position the exposed portion of the cable braid directly in line with the

clamp.

3. Tighten the clamp screws. Torque value 2.0 N•m (17.7 lb•in) max.
4. Repeat

step 1

through

step 3

for each drive in multi-axis configurations.

Motor Cable

Shield Clamp

Motor Power
(MP) Connector

Motor Brake
(BC) Connector

Exposed shield braid
under clamp.

Shield Clamp Screws (2)

Feedback cable routed

within the shield braid.

Kinetix 5500 Servo Drives,

Frame 2 or 3, Front View

(frame 2 is shown)

2198-KITCON-DSL

Motor Feedback

Connector Kit

Retention Screw

(loosen, do not remove)

Clamp features apply to all

frame sizes.

Torque clamp screws to

2.0 N•m (17.7 lb•in), max

Bulletin 2090 Single Motor Cable