beautypg.com

Kinetix 5500 system current demand example – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 221

background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

221

Sizing Multi-axis Shared-bus Configurations

Appendix C

Table 89 - Control Power Current Demand

Kinetix 5500 System Current Demand Example

In this example, the Kinetix 5500 drive system includes two 2198-H040-ERS
drives, four 2198-H008-ERS drives, and one capacitor module.

Figure 106 - Shared AC/DC Hybrid Configuration

Table 90 - Kinetix 5500 System Current Demand Calculations

Cat. No.

24V Current
(non-brake motor)
A

DC

24V Current
(2 A brake motor)
A

DC

24V Inrush Current

(1)

A

(1) Inrush current duration is less than 30 ms.

2198-H003-ERSx

0.4

2.4

2.0

2198-H008-ERSx

2198-H015-ERSx

0.8

2.8

3.0

2198-H025-ERSx

2198-H040-ERSx

2198-H070-ERSx

1.3

3.3

2198-CAPMOD-1300

0.3

N/A

2.0

Bonded Cabinet
Ground

Three-phase

Input Power

24V Input

Control Power

3.5 A min, non-brake motors

15.2 A min, brake motors

2198-H040-ERS

Servo Drives

2198-H008-ERS

Servo Drives

2198-CAPMOD-1300 Capacitor Module

DC Bus Connections

Kinetix 5500 Module
Cat. No.

Qty

24V Current
(non-brake motors)
A

DC

24V Current
(2 A brake motors)
A

DC

24V Inrush Current

(1)

A

(1) Inrush current duration is less than 30 ms.

2198-H008-ERSx

4

0.4 x 4 = 1.6

2.4 x 4 = 9.6

2 x 4 = 8

2198-H040-ERSx

2

0.8 x 2 = 1.6

2.8 x 2 = 5.6

3 x 2 = 6

2198-CAPMOD-1300

1

0.3 x 1 = 0.3

N/A

2 x 1 = 2

Total current demand 3.5

15.2

16