beautypg.com

Wiring the digital input connectors, Wire the safe torque-off connector, Table 35 – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 79

background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

79

Connecting the Kinetix 5500 Drive System

Chapter 5

Figure 44 - IPD Connector Wiring - Shared Bus

Table 35 - Shared Bus IPD Connector Wiring Specifications

Wiring the Digital Input
Connectors

This section provides guidelines to assist you in making digital input
connections.

Wire the Safe Torque-off Connector

For the hardwired safe torque-off (STO) connector pinouts, feature descriptions,
and wiring information, refer to

Chapter 9

beginning on

page 157

.

L3

L2

L1

Kinetix 5500 Drives
Top View

Mains AC Input

Wiring Connector

Kinetix 5500 Drive
Cat. No.

Pin

Signal

Input Current, max
A rms

Recommended
Wire Size
mm

2

(AWG)

Strip Length
mm (in.)

Torque Value
N•m (lb•in)

2198-H003-ERSx
2198-H008-ERSx
2198-H015-ERSx
2198-H025-ERSx
2198-H040-ERSx

52

13.3…3.3
(6…12)

11.0 (0.43)

1.7…1.8
(15.0…15.9)

2198-H070-ERSx

13.3 (6)

L3
L2
L1

L3
L2
L1