Setup screens – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual
Page 102
102
Rockwell Automation Publication 2198-UM001D-EN-P - May 2014
Chapter 6
Configure and Start the Kinetix 5500 Drive System
Setup Screens
The setup screens provide the means of changing drive settings, for example, the
IP address. Press one of the SETUP buttons to access the setup screens.
You can use the soft menu items and navigation buttons to
view the information and make changes.
Press
to validate your changes:
• If the change is invalid, the value doesn’t change.
• If the change is valid, an asterisk appears next to the
changed attribute.
Table 52 - Navigating the Settings Menu
IMPORTANT
You must cycle control power to make network configuration changes
persistent. In this example, the IP address was changed. The change takes
affect and the asterisk disappears after control power is cycled.
Display configuration changes take effect immediately.
SETTINGS
DISPLAY
ESC
NETWORK
STATIC IP
SUBNET MASK
ESC
IP ADDRESS*
Settings Menu Selections
Sub Menu Selections
Attributes
Default
Description
Network
->Static IP
(1)
IP address
192.168.1.1
Indicates current IP address
Subnet mask
255.255.255.000
Indicates current subnet mask
Gateway
192.168.001.001
Indicates current gateway
DHCP
On
Turns DHCP on
Off
Turns DHCP off
Display
Backlight Timeout
30 sec…NEVER
(NEVER=no timeout period,
the backlight is always on)
-> 3 min
(1)
Sets backlight timeout period of the display
Contrast
-10…+10
0
Contrast setting of the display
Cyclic Data Select
(2)
->DC BUS
(1)
DC bus voltage
ENC TEMP
Encoder temperature in °C
INV UTIL
Inverter utilization in percent
INV TEMP
Inverter temperature in °C
CONV UTIL
Converter utilization in percent
CONV TEMP
Converter temperature in °C
SHUNT UTIL
Shunt utilization in percent
MOTOR UTIL
Motor utilization in percent
SPEED
RPM
OUT PWR
Output power in watts
OUT FREQ
Output frequency in hertz
OUT CUR
Output current in amps
(1) An arrow (->) appears in front of the chosen attribute indicating that this attribute is currently configured. This is also the factory default setting.
(2) The DC bus voltage is one of several cyclic data attributes. You can select any of the Cyclic Data Select attributes to be displayed on the Home screen.