Shared ac/dc configurations – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual
Page 216
![background image](/manuals/580509/216/background.png)
216
Rockwell Automation Publication 2198-UM001D-EN-P - May 2014
Appendix C
Sizing Multi-axis Shared-bus Configurations
Shared AC/DC Configurations
In a shared AC/DC configuration, the first (leftmost) drive receives AC input
voltage. The shared-bus connection system extends the AC and DC bus to all
downstream drives:
• All drives are configured in the project file as Shared AC/DC drives.
• Drives must be of the same power rating (catalog number).
• Shared AC/DC configurations support Bulletin 2198 capacitor modules
• Total available converter power is derated by 30%.
• The maximum number of drives configured as Shared AC/DC is
described in
Table 87
.
Table 87 - Shared AC/DC Panel Layout
Figure 101 - Typical Shared AC/DC Configuration
For an example shared AC/DC installation with additional details, refer to
Typical Shared AC/DC Installations
Drive Cat. No.
Frame Size
Drives Configured as Shared AC/DC, max
(1)
(1) For Bulletin 2198 capacitor module maximum values, refer to the Kinetix 5500 Capacitor Module Installation Instructions,
publication
.
Number of Capacitor
Modules, max
2198-H003-ERSx
1
8
0
2198-H008-ERSx
1
2198-H015-ERSx
2
4
4
2198-H025-ERSx
2198-H040-ERSx
2198-H070-ERSx
3
2
4
Bonded Cabinet
Ground
Three-phase
Input Power
Kinetix 5500 Servo Drives
(top view)
24V Input
Control Power
DC Bus Connections
2198-CAPMOD-1300 Capacitor Module
(optional component)