Sizing Multi-axis Shared-bus Configurations

Appendix C

Shared AC/DC Hybrid Configurations

In shared AC/DC hybrid configurations, three-phase AC input power is
supplied to two or more (leader) drives that act as converters. This parallel
converter configuration increases the DC power supplied to the inverter
(follower) drives:

The leftmost drives in a hybrid configuration act as parallel converter

drives and must be of the same power rating (catalog number).

Shared DC (inverter) drives mounted to the right of the shared AC/DC

(converter) drives must have the same or lower power rating (catalog
number) than the shared AC/DC drives.

The total motoring load must not exceed the rated load for the drives

sourcing the DC power. Each follower drive must be sized for the motor
load connected to it.

Total available converter power is derated by 30%.
The maximum number of drives configured in the project file as

Shared AC/DC is restricted according to

Table 87 on page 216

.

The maximum number of drives configured in the project file as

Shared DC is restricted according to

Table 86 on page 215

.

Shared AC/DC hybrid configurations support Bulletin 2198 capacitor

modules.

Figure 102 - Typical Shared AC/DC Hybrid Configuration

(1) For Bulletin 2198 capacitor module maximum values, refer to the Kinetix 5500 Capacitor Module Installation Instructions,

publication

2198-IN004

.

For an example shared AC/DC hybrid installation with additional details, refer
to

Typical Shared AC/DC Bus Hybrid Installations

on

page 19

.

Bonded Cabinet
Ground

Three-phase

Input Power

24V Input

Control Power

2198-H040-ERSx

Common-bus (converter)

Leader Drives

2198-H008-ERSx

Common-bus (inverter)

Follower Drives

2198-CAPMOD-1300 Capacitor Module

(1)

(optional component)

DC Bus Connections